| Brand | Teledyne LeCroy |
|---|---|
| Bandwidth | 350 MHz – 2 GHz |
| Analog Channels | 8 |
| Max. Axq. Mem. | 50 Mpts |
| Max Sample Rate | 10 GS/s |
WaveRunner 8000HD Oscilloscopes
The Teledyne LeCroy WaveRunner 8000HD is a High Definition oscilloscope designed to capture every signal detail with absolute precision. It features 12-bit resolution all the time and provides 8 analog channels alongside 16 digital channels for maximum flexibility. This series is ideal for complex debugging, offering 5 Gpt memory records without performance tradeoffs.
Key Specifications & Features
- Resolution: 12 bits all the time (HD4096 technology)
- Analog Channels: 8 high-definition inputs
- Digital Channels: 16-channel MSO capability
- Memory Depth: Up to 5 Gpt records with simple navigation
- Multi-Scope Sync: OscilloSYNC allows viewing 16 channels on one display
- Power Analysis: Optional 3-phase harmonics, vector, and dq0 transforms
- Jitter Analysis: Clock Expert and JITKIT frameworks available
- Signal Analysis: Spectrum Analyzer and VectorLinQ VSA options
| WR8KHD-EMC | EMC Pulse Parameter Software Package for WaveRunner/MDA 8000HD |
| WR8KHD-SPECTRUM-1 | Spectrum Analyzer for WaveRunner 8000HD – 1 trace |
| WR8KHD-SPECTRUM-PRO-2R | Spectrum Analyzer for WaveRunner 8000HD – 2 traces + reference |
| WR8KHD-THREEPHASEHARMONICS | 3-phase Harmonics Calculation Option for WaveRunner/MDA 8000HD |
| WR8KHD-VECTORLINQ | VectorLinQ Vector Signal Analysis for WaveRunner/MDA 8000HD |
| WR8KHD-THREEPHASEVECTOR | 3-phase Vector Display option for WaveRunner and MDA 8000HD |
| WR8KHD-XDEV | Advanced Customization Option for WaveRunner/MDA 8000HD |
| WR8KHD-THREEPHASEDQ0 | 3-phase dq0 Transform option for WaveRunner and MDA 8000HD |
| WR8KHD-ZONETRIGGER | ZoneTrigger option for WaveRunner/MDA 8000HD |
| WR8KHD-PWR | Power Analysis Option for WaveRunner/MDA 8000HD |
| WR8KHD-POWER-DEVICE | Power Device Analysis Option for WaveRunner/MDA 8000HD |
| WR8KHD-DIG-PWR-MGMT | Digital Power Management Analysis Option for WaveRunner/MDA 8000HD |
| Jitter Analysis Software | |
| WR8KHD-CLOCK-X | Clock Expert Jitter Analysis Framework |
| WR8KHD-CLOCK-X-PRO | Clock Expert Jitter Analysis Framework with SSC, Phase Noise and Accumulated Jitter Analysis |
| WR8KHD-JITKIT | Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay |
| Digital Filtering Software | |
| WR8KHD-DFP2 | Digital Filter Software Package for WaveRunner/MDA 8000HD |
| WR8KHD-SDM | Serial Data Mask Software Package for WaveRunner/MDA 8000HD |
| WR8KHD-VIRTUALPROBE | Advanced De-embedding, Emulation and Virtual Probing Toolkit |
WaveRunner 8000HD Oscilloscopes
The Teledyne LeCroy WaveRunner 8000HD series delivers the highest resolution in its class, providing 12-bit performance at all times for superior signal fidelity. With 8 analog channels and the capacity for 16 digital channels, it offers more inputs and flexibility than typical oscilloscopes. This platform is specifically designed to handle long memory records up to 5 Gpt, ensuring users can capture long-duration events without sacrificing high sample rates or navigation speed. Engineered with HD4096 high-definition technology, the WaveRunner 8000HD maintains high resolution across its entire bandwidth, making it the perfect tool for power electronics and embedded system testing. The inclusion of OscilloSYNC technology allows for the synchronization of two units, enabling a seamless 16-channel viewing experience on a single display. This construction ensures that complex multi-rail power systems and high-speed control signals can be analyzed simultaneously with ease. The series is highly customizable through an extensive range of software options, including specialized packages for EMC pulse parameters and power device analysis. Users can expand their testing capabilities with the Spectrum Analyzer option, VectorLinQ for vector signal analysis, or advanced jitter frameworks like Clock Expert. With available options for 3-phase harmonics and digital power management, the WaveRunner 8000HD adapts to the most demanding technical requirements in modern engineering labs.HD4096 High Definition Technology
Provides 12-bit resolution at all times for the highest signal fidelity and precision.
Industry-Leading 5 Gpt Memory
Capture long-duration waveforms with high sample rates using the longest memory in its class.
OscilloSYNC 16-Channel View
Synchronize two oscilloscopes to view and analyze 16 analog channels on a single display.
Extensive Software Customization
Tailor the scope with options for EMC, Spectrum Analysis, 3-phase power, and advanced jitter tools.
Unmatched 12-Bit Resolution and Channel Density
The WaveRunner 8000HD provides 12-bit resolution all the time, offering 16 times more quantization levels than standard 8-bit instruments for precise signal characterization. This high-definition performance is combined with an 8-channel architecture, allowing engineers to monitor more points of interest simultaneously in complex power conversion and automotive systems.
Advanced Power and Signal Integrity Analysis
Equipped with specialized software options, this series supports comprehensive 3-phase power analysis, including harmonics calculation and dq0 transformations. For signal integrity tasks, the Clock Expert and Jitter Analysis frameworks provide deep insights into phase noise, accumulated jitter, and spectral views, ensuring robust performance in high-speed digital designs.