| Brand | Gustav Klein |
|---|---|
| Safety level | Performance Level d (ISO 13849-1 / EN 60204-1) |
| Application | Parallel connection of 2x I-TS-3840 / 3842 / 3870 |
| Enclosure options | Wall-mounted (600x250x800 mm), floor-standing (800x800x2000 mm), or PDSB-integrated |
Safety Master for Parallel Operation
Key Features
- Restores Performance Level d (PLd) when operating two I-TS units in parallel
- Safety controller communicating with the safety controllers of both I-TS units
- Mode selector switch for single or parallel operation
- Available as a dedicated control cabinet, a wall-mounted IP54 enclosure, or integrated into a PDSB
- Includes the required wiring and safety assessment for the parallel connection
| Model | Description |
|---|---|
| I-TS-Master 3.0_wall | Wall-mounted enclosure, 600x250x800 mm. |
| I-TS-Master 3.0_floor | Control cabinet, 800x800x2000 mm. |
| I-TS-Master-PDSB 3.0 | For installation in a PDSB. |
Safety Master for Parallel Operation
An individually operated I-TS achieves Performance Level d (PLd) per ISO 13849-1 / EN 60204-1. In parallel operation, combining multiple I-TS units loses that performance level unless it is restored through dedicated wiring and a safety assessment between the units — which the Safety Master provides for parallel connection of two I-TS-3840, I-TS-3842 or I-TS-3870 units.Who Is the Safety Master For?
Test engineers combining two I-TS-3840, I-TS-3842 or I-TS-3870 units in parallel who need to maintain Performance Level d (PLd) in that configuration, without carrying out a custom safety assessment themselves.Available Models & Accessories
The Safety Master is available as a wall-mounted enclosure, a floor-standing control cabinet, or a module for installation directly in a PDSB.Parallel operation without losing safety level
Combining two I-TS units normally drops below Performance Level d; the Safety Master's wiring and safety assessment restore it.
Single or parallel is a switch, not a rebuild
The mode selector switch lets the same setup run as two independent units or as one parallel system.
Fits the installation, not the other way round
Available as a wall enclosure, a floor-standing cabinet, or a module inside an existing PDSB.
The safety assessment comes with the product
GK delivers the wiring and safety assessment as part of the Safety Master, rather than leaving that engineering step to the customer.