| Brand | Pacific Power Source |
|---|---|
| Max. power (single cabinet) | 6-216 kW |
| Voltage range (constant power) | 30-350 L-N / ±475 Vdc |
| Frequency range (standard) | 15-1200 Hz |
| Regenerative power | >90 % |
| Communication Interfaces | RS-232, USB, Modbus, TCP, GPIB, SCPI |
RLS Series Regenerative AC/DC Load Simulator
Key Features
- Regenerative 4-quadrant AC/DC load
- High power density, up to 24 kVA in 4U
- Wide operating envelope, highest current availability
- AC, DC output in six form configurations
- Regenerative power recovery over 90%
- Three-phase high-power systems up to 1.296 MVA/MW
- PowerFlex: order the power rating you need today and expand output later as requirements grow, without a service visit or hardware exchange
| Model | Description |
|---|---|
| 360RLS | 6 kW, 4U. Voltage range 30-350V L-N. |
| 390RLS | 9 kW, 4U. Voltage range 30-350V L-N. |
| 3120RLS | 12 kW, 4U. Voltage range 0-350V L-N (the only RLS model starting at 0V rather than 30V). |
| 3150RLS | 15 kW, 4U. Voltage range 30-350V L-N. |
| 3180RLS | 18 kW, 4U. Voltage range 30-350V L-N. |
| 3210RLS | 21 kW, 4U. Voltage range 30-350V L-N. |
| 3241RLS | 24 kW, 4U. Voltage range 30-350V L-N. |
| 3300RLS-4UC | 30 kW, 8U parallel cabinet. |
| 3360RLS-4UC | 36 kW, 18U parallel cabinet. |
| 3481RLS-4UC | 48 kW, 18U parallel cabinet. |
| 3630RLS-4UC | 63 kW, 18U parallel cabinet. |
| 3721RLS-4UC | 72 kW, 18U parallel cabinet. |
| 3961RLS-4UC | 96 kW, 32U parallel cabinet. |
| 31050RLS-4UC | 105 kW, 32U parallel cabinet. |
| 31201RLS-4UC | 120 kW, 32U parallel cabinet. |
| 31441RLS-4UC | 144 kW, 32U parallel cabinet. |
| 31681RLS-4UC | 168 kW, 42U parallel cabinet. |
| 31921RLS-4UC | 192 kW, 42U parallel cabinet. |
| 32161RLS-4UC | 216 kW, 42U parallel cabinet. Custom three-phase high-power systems up to 1.296 MVA/MW available on request. |
| Option | Description |
| C | Interharmonics for currents. |
RLS Series Regenerative AC/DC Load Simulator
The RLS Series is a programmable AC and DC electronic load for testing AC and DC load applications. The 4-quadrant load offers several AC and DC emulation modes and flexible single, split and three-phase configurations, with steady-state or transient execution. Power density reaches 24 kW in a 4U chassis, up to 216 kW in a single cabinet, up to 432 kW in dual paralleled cabinets, and up to 1.296 MVA/MW in custom three-phase, high-power systems on request.Who Is the RLS For?
Test engineers validating EV charging and V2G equipment, on-board chargers and EVSEs, grid-tied and smart-grid equipment, solar inverters and energy storage systems, and general burn-in/production testing of UPS, power supplies, DC-DC converters and battery systems.Constant power voltage range eliminates range-switching.
A single constant-power voltage range (30-350V L-N / ±475Vdc) delivers both higher current at lower voltage and higher voltage at lower current without switching ranges.
Highest current availability for AC load simulation.
The RLS provides a broader current range than typical competing units, up to 20% more current, reducing the risk of over- or under-sizing the test power source.
Full 4-quadrant operation for leading and lagging power flows.
The regenerative AC/DC load draws both true and apparent power bidirectionally, with programmable control over power factor, crest factor and current waveshape.
Built-in SmartSource Suite for remote control.
An embedded web-browser interface gives full remote control, development and real-time execution of test sequences from any device.