| Brand | Gustav Klein |
|---|---|
| Current rating | 1000-4000 A |
| Cabinet Dimensions | 1000x310x1000 to 600x600x1900 mm (current-dependent) |
| Protection Class | IP54 |
| Safety | Door contact switch, stop/reset button, signal column |
PDU Power Distribution Unit
Key Features
- Connection of (M)I-TS output and test specimen to copper busbars, with earth and shielding busbars
- Voltmeter for the applied DC voltage, sense-line connection with fuse
- Safety control connected to the (M)I-TS, stop button (black, mushroom-shaped) with reset
- Door contact switch with safe shutdown when opened
- Signal column: red (fault/emergency stop), yellow (ready), green (test mode), white (stop)
- IP54 protection class
| Model | Description |
|---|---|
| (M)I-TS-PDU-1000 | 1000 A, 1 input / 1 output, control cabinet, IP54. |
| (M)I-TS-PDU-2000 | 2000 A, 2 inputs / 1 output, control cabinet, IP54. |
| (M)I-TS-PDU-4000 | 4000 A, 4 inputs / 1 output, control cabinet, IP54, dimensions on request. |
| Option | Description |
| Cap-MKP | MKP capacitors in PDU, to reduce DUT interference (2x 280 uF). |
| short-circuit-bracket | Short-circuit bracket for safe maintenance work (max. 1600 A, not applicable for batteries as DUT). |
| PDU-ADD-DIODE-1000 | Protection diode 1000 A, prevents source operation (e.g. fuel cell testing). |
| PDU-ADD-DIODE-2000 | Protection diode 2000 A, prevents source operation. |
| (M)I-TS-DOORL | Door interlock (safety door lock, magnetic). |
PDU Power Distribution Unit
The PDU is used for local connection of the test specimen when the I-TS or MI-TS is installed some distance from the test chamber. Depending on current rating, it is a control cabinet or a wall-mounted IP54 enclosure with connection busbars, safety control and status indication.Who Is the PDU For?
Test engineers whose I-TS or MI-TS system is physically separated from the test chamber and who need a local, safety-integrated connection point for the test specimen, with clear status indication for anyone working at the bench.Available Models & Accessories
The PDU is available for 1000 A, 2000 A and 4000 A, each with 1 or 2 inputs and 1 output. Options add MKP capacitors to reduce DUT interference, a short-circuit bracket for safe maintenance, protection diodes to prevent source operation, and a door interlock.Keeps the test chamber connection local
When the I-TS/MI-TS sits at a distance, the PDU brings busbars, safety control and status indication to the point where the test specimen actually connects.
Signal column gives status at a glance
Red, yellow, green and white indicators communicate fault, ready, test mode and stop without needing to check the (M)I-TS display.
Protection options match the test object
A protection diode variant blocks source operation, useful for fuel cell testing, and a short-circuit bracket allows safe maintenance work (except on battery DUTs).
Scales from 1000 A to 4000 A in the same product line
One PDU concept covers a wide current range, from a compact wall enclosure to a larger control cabinet.
Request for quote
Looking for a custom solution or a tailored offer? Please fill out the form below, and we’ll get back to you as soon as possible with a personalized quote.