| Brand | Pacific Power Source |
|---|---|
| Rated apparent power | 60+ kVA |
| Rated current (per phase) | 16-75 A |
| Emissions standards | IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Immunity standards | IEC 61000-4-11, IEC 61000-4-13, IEC 61000-4-14, IEC 61000-4-17, IEC 61000-4-27, IEC 61000-4-28, IEC 61000-4-29, IEC 61000-4-34 |
| Calibration standard | ISO 17025 |
SmartTS-HFI Harmonics, Flicker, and Immunity Test System
The SmartTS-HFI Harmonics, Flicker, and Immunity Test System is an integrated EMC compliance test platform that combines harmonics and flicker emissions testing with power line immunity testing in a single, automated system. It covers equipment under test up to 75 A per phase, in single- and three-phase configurations, with six current-rated variants available from 16 A to 75 A.
Key Specifications & Features
- Combines emissions testing (harmonics, flicker) and immunity testing (voltage dips, interruptions, unbalance, frequency variation) in one platform, where earlier generations required separate systems
- Windows-based software enforces correct EUT classification, standard selection and test sequencing
- Real-time harmonics and flicker measurement with automatic pass/fail determination against the applicable IEC class
- Automatically generates IEC-ready compliance test reports at the end of each run
- ISO 17025 calibrated measurement system with full data capture and logging
- Scales from single-phase 16 A validation to three-phase 75 A high-current testing on one architecture
| Model | Type | Summary |
|---|---|---|
| SmartTS-HFI-3-75A | Model | Three-phase, 75 A per phase, highest-current variant, compatible with the EPTS-75A module for full IEC 61000-4-11/-27/-34 immunity testing up to 75 A. |
| SmartTS-HFI-3-40A | Model | Three-phase, 40 A per phase, compatible with the EPTS-32A module. |
| SmartTS-HFI-3-32A | Model | Three-phase, 32 A per phase, compatible with the EPTS-32A module. |
| SmartTS-HFI-3-16A | Model | Three-phase, 16 A per phase, compatible with the EPTS-16A module. |
| SmartTS-HFI-1-16A | Model | Single-phase, 16 A, compatible with the EPTS-16A module. |
| SmartTS-HF-1-16A | Model | Single-phase, 16 A. Harmonics and flicker emissions testing only; immunity testing (EPTS) is not supported on this variant. |
| EPTS Module | Option | Electronic Power Transfer Switch module (16 A / 32 A / 75 A ratings), using solid-state transfer-switch technology for full compliance with IEC 61000-4-11, IEC 61000-4-27 and IEC 61000-4-34, with voltage transition times under 5 ms. Requires a programmable AC source plus an AC mains connection or fixed generator supplying unperturbed voltage. |
SmartTS-HFI Harmonics, Flicker, and Immunity Test System
The SmartTS-HFI is an integrated EMC compliance test platform that combines harmonics and flicker emissions testing (IEC 61000-3) with power line immunity testing (IEC 61000-4) in a single, automated system. It covers equipment under test up to 75 A per phase, in single- and three-phase configurations, and is available in six current-rated variants from 16 A to 75 A. The SmartTS-HFI replaces the ECTS2 Series as Pacific Power Source's current-generation harmonics and flicker platform.One platform for both emissions and immunity testing.
Earlier-generation harmonics/flicker systems and immunity test setups typically ran as separate equipment; the SmartTS-HFI integrates measurement, power generation, and automated workflow into a single scalable system.
Software-enforced test discipline.
The Windows-based control software fixes EUT classification, standard selection, and test sequencing, so IEC 61000-3/4 test runs follow the correct procedure rather than depending on operator judgment.
Audit-ready output by design.
ISO 17025 calibration combined with automatic, IEC-ready report generation at the end of every run gives a documented, traceable result without separate report assembly.
One architecture from bench validation to full-compliance testing.
Six variants span single-phase 16 A up to three-phase 75 A, with the EPTS module adding sub-5 ms voltage transfer switching for full IEC 61000-4-11/-27/-34 immunity compliance when required.
Who Is the SmartTS-HFI For?
Aerospace and compliance certification labs, electric vehicle and EV charging infrastructure testing, smart grid and utility grid equipment validation, household appliance manufacturers, and university or research laboratories running IEC 61000-3/61000-4 compliance work.
Available Models & Accessories
Six models cover single- and three-phase configurations from 16 A to 75 A per phase; the SmartTS-HF-1-16A is a reduced-capability entry variant limited to harmonics and flicker emissions testing, without the immunity (EPTS) option. Every SmartTS-HFI variant runs on Pacific Power Source’s AZX, AGX or AFX series AC/DC sources. The EPTS Module is available as an option across the SmartTS-HFI models for full immunity compliance testing.
Request for quote
Looking for a custom solution or a tailored offer? Please fill out the form below, and we’ll get back to you as soon as possible with a personalized quote.