VIS Series Voltage interruptions, variations and dips Simulators

Schlöder GmbH

The Schlöder VIS 1700 simulates voltage dips, short-term interruptions, and voltage fluctuations to test electrical and electronic equipment immunity per IEC 61000-4-11 (AC) and IEC 61000-4-29 (DC). It handles single- and three-phase equipment up to 16 A per conductor, simulating 100% interruptions, dips via external step transformer, and gradual fluctuations with an automatic ramp function, plus inrush current measurement.

Key Features

  • Compliant with IEC 61000-4-11 (AC) and IEC 61000-4-29 (DC)
  • Single- and three-phase testing up to 16 A per conductor
  • 100% voltage interruption simulation (AC & DC)
  • Voltage dips via external step transformer (VIS 740)
  • Automatic ramp function for voltage fluctuations
  • Inrush current measurement
  • Control software included

Typical Applications

  • CE/EMC compliance testing
  • Power supply & appliance qualification
  • Industrial equipment mains-resilience testing
  • In-house pre-compliance & R&D testing
Overview & Applications
BrandSchlöder GmbH
StandardsIEC 61000-4-11 (AC), IEC 61000-4-29 (DC)
Max Current16 A per conductor
PhasesSingle-phase and three-phase
ApplicationsCE/EMC, power supply, industrial mains resilience, R&D
ModelDescription
OptionDescription
Voltage interruption simulator according to IEC 61000-4-11, AC and DC ramp function, includes factory calibration VIS 1700-1
VIS 740Step transformer 16,0 A for voltage dips, AC using only, 0%, 40%, 70%, 80% – necessary to reach the requirement acc. IEC 61000-4-11

No downloads available.

The Schlöder VIS 1700 is a voltage interruption and dip simulator designed to test the immunity of electrical and electronic equipment to mains supply disturbances per IEC 61000-4-11 (AC) and IEC 61000-4-29 (DC). It simulates the full range of disturbances specified in both standards: 100% voltage interruptions, voltage dips to defined percentage levels, and gradual voltage fluctuations via an automatic ramp function.

Single- and three-phase equipment up to 16 A per conductor can be tested directly. Voltage dips to 0%, 40%, 70%, and 80% of nominal are generated via the external VIS 740 step transformer accessory, which provides the precise switching required for IEC 61000-4-11 compliance. The instrument also measures inrush current during interruption recovery, providing additional data relevant to power supply and appliance qualification.

Control software is included as standard, and factory calibration is supplied with the VIS 1700-1 model, supporting use in accredited test laboratories.

IEC 61000-4-11 & -4-29

AC and DC voltage dip, interruption and fluctuation simulation in one instrument.

Up to 16 A per phase

Single- and three-phase testing up to 16 A per conductor for equipment and power supplies.

Automatic ramp function

Automatic ramp function for gradual voltage fluctuation testing and inrush current measurement.

Factory calibration included

Supplied with factory calibration and control software for accredited laboratory use.

View Models & Options

Request for quote

Looking for a custom solution or a tailored offer? Please fill out the form below, and we’ll get back to you as soon as possible with a personalized quote.

    Other products & series