OMNIA II

OMNIA II Series

Multifunction Electrical Safety Compliance Analyzer


Model 8204 is a 4-in-1 Electrical Safety Compliance Analyzer that performs AC Hipot, DC Hipot, 40 Amp Ground Bond and Insulation Resistance testing in a single instrument. Model 8254 adds 500 VA test functionality to the model 8204. Model 8206 is a 6-in-1 Electrical Safety Compliance Analyzer that performs AC Hipot, DC Hipot, 40 Amp Ground Bond, Insulation Resistance, Functional Run and Line Leakage testing in a single instrument. Model 8256 adds 500 VA test functionality to model 8206. Model 8207 is a 7-in-1 Electrical Safety Compliance Analyzer that performs AC Hipot, DC Hipot, 40 Amp Ground Bond, Insulation Resistance, Functional Run and Line Leakage testing while adding a built-in 500 VA AC power source in a single instrument. Model 8257 adds 500 VA test functionality to the model 8207.

  • 4-in-1, 5-in-1 and 6-in-1 fully automated testers
  • 500 VA models available
  • Autoware Software (optional)
  • Color TFT Display – Color Code test results
  • “My Menu” Interface- personalize user interface
  • Built-in Power Source – model 8207 & 8257
  • DualCHEK® – Performs Hipot and Ground Bond test simultaneous
  • Multiple Automation Interfaces – Select your preffered interface at no extra cost
  • Expanded Test Memories- store and recall up to 10.000 test steps
  • Patented SmartGFI® function – Safety feature to protect operator
  • Patented Prompt and Hold function – Insert operator instructions (text, picture, video)
  • Patented CAL-ALERT® function
  • Patented VERI-CHEK® function – Built in self test
  • CHARGE LO® – detects if cables are connected correct in DC mode
  • RAMP HI® – Enables faster testing in DC hipot mode
  • AC/DC OFFSET – Eliminates test fixture and cables
  • True RMS Current – Accurately measure leakage current
  • 3 Years warranty
  • Fast delivery

 

 Model Hipot IR Ground Bond Run Leakage Current Test
8204 5 kV @ 30 mA AC
6 kV @ 20 mA  DC
30–1000 VDC
0.05 MΩ-50.0 GΩ
1.00- 40.00 A
0-600 mΩ
8254 5 kV @ 100 mA AC
(500 VA)*
6 kV @ 20 mA  DC
30–1000 VDC
0.05 MΩ-50.0 GΩ
1.00- 40.00 A
0-600 mΩ
8206 5 kV @ 30 mA AC
6 kV @ 20 mA  DC
30–1000 VDC
0.05 MΩ-50.0 GΩ
1.00- 40.00 A
0-600 mΩ
0-277 V AC
0-16 A
0.1 µA-10.00 mA (pk & rms)
Internal Measuring Devices
Neutral, Gnd. Polarity Fault
8256 5 kV @ 100 mA AC
(500 VA)*
6 kV @ 20 mA  DC
30–1000 VDC
0.05 MΩ-50.0 GΩ
1.00- 40.00 A
0-600 mΩ
0-277 V AC
0-16 A
0.1 µA-10.00 mA (pk & rms)
Internal Measuring Devices
Neutral, Gnd. Polarity Fault
OMNIA II Models with Internal 630 VA (500 Watt) AC Power Source
8207 5 kV @ 30 mA AC
6 kV @ 20 mA  DC
10-6000 V
0.1 MΩ-50.0 GΩ
1.00-40.00 A
0-600 mΩ
0-277 V AC
0-16 A
0.1 µA-10.00 mA (pk & rms)
Internal Measuring Devices
Neutral, Gnd. Polarity Fault
8257 5 kV @ 100 mA AC
(500 VA)*
6 kV @ 20 mA  DC
30–1000 VDC
0.05 MΩ-50.0 GΩ
1.00-40.00 A
0-600 mΩ
0-277 V AC
0-16 A
0.1 µA-10.00 mA (pk & rms)
Internal Measuring Devices
Neutral, Gnd. Polarity Fault

*Meets 200 mA short circuit requirement

OMNIA II Introduction


Setting Up Tests


OMNIA II and scanners


Advanced Testing Applications


Setting up Line Leakage and Functional Run tests