22.5 kVA – 135 kVA High output AC and DC power system
The MX Series consists of multiple high power AC and DC power systems that provide controlled AC and DC output for ATE and product test applications.
This high power AC and DC test system covers a wide spectrum of AC and DC power applications at an affordable cost. Using state-of-the-art PWM switching techniques, the MX series combines compactness, robustness and functionality in a compact floor-standing chassis, no larger than a typical office copying machine. This higher power density has been accomplished without the need to resort to elaborate cooling schemes or additional installation wiring. Simply roll the MX22,5, MX30, or MX45 unit to its designated location (using included casters), plug it in, and the MX series is ready to work for you.
- High Power AC and DC Power Source
- Programmable AC and DC power for frequency conversion and product test applications
- Expandable Power Levels
- Available output power of 22.5, 30, and 45 kVA per unit and multi-unit configurations for power
requirements up to 135 kVA and above
- Available output power of 22.5, 30, and 45 kVA per unit and multi-unit configurations for power
- Single and Three Phase Mode
- Phase mode programming on MX22.5-3Pi, MX30-3Pi and MX45-3Pi allows switching between single and
three phase output modes
- Phase mode programming on MX22.5-3Pi, MX30-3Pi and MX45-3Pi allows switching between single and
- Arbitrary & Harmonic Waveform Generation
- User defined voltage waveform and distortion programming
- Regenerative, bidirectional “Green” Power Solution
- Automatic crossover between Source and Sink power mode offers regenerative capabilities in AC
mode. Regenerate up to 100% of the rated output power back to the utility grid during sink mode
operation. ( -SNK option )
- Automatic crossover between Source and Sink power mode offers regenerative capabilities in AC
- Remote Control
- Standard RS232C & USB along with optional IEEE- 488 & LAN Interfaces are available for automated
test applications
- Standard RS232C & USB along with optional IEEE- 488 & LAN Interfaces are available for automated
Model | Power | Phases | #Cabinets | Output Voltage | Frequency Range |
Single Cabinet | |||||
MX22.5-3Pi-400R | 22.5 kVA | 1/3 | 1 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
MX30-3Pi-400R | 30 kVA | 1/3 | 1 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
MX45-3Pi-400R | 45 kVA | 1/3 | 1 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
Multi-Cabinet (consisting of Master and Slave units) |
|||||
MX60-3Pi-400R | 60 kVA | 3 | 2 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
MX60-3Pi-MB-400R* | 60 kVA | 3 | 2 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
MX90-3Pi-400R | 90 kVA | 3 | 2 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
MX90-3Pi-MB-400R* | 90 kVA | 3 | 2 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
MX135-3Pi-400R | 135 kVA | 3 | 3 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
MX135-3Pi-MB-400R* | 135 kVA | 3 | 3 | 150 V/300Vac 200/400 Vdc |
DC, 16 Hz – 819 kHz (905 Hz option) |
*-MB Multi Box variants offer additional controller in each slave unit allowing master and slaves to be used as separate individual AC/DC Power Sources |