TBJT01
The TBJT01 is a wideband injection transformer for control loop stability measurements. It provides galvanic isolation between the swept signal source and the control loop. Theinjection transformer is internally terminated with a 5 Ohm resistor and protected with a 100 mA fuse. The usable frequency range is 10 Hz to 45 MHz=
- Compliance: RoHS
- Termination resistor: 5 Ω
- Fuse: 100 mA (Littlefuse 0451.100MRL); secondary (output) side
- Turns ratio: 1:1
- Characterized freq. range: 1 Hz to 100 MHz
- Usable frequency range: 10 Hz – 45 MHz
- 3 dB frequency range: 15 Hz – 9 MHz typ.
- Insertion loss (S21): 15.5 dB typ.
- Capacitance: 90 pF @ 1 Khz; primary to secondary winding
- DC saturation current: 12 mA
- Max. voltage rating: 600V CAT II; primary to secondary winding
- Input connector: 50 Ω BNC female,
- Output connector: 4 mm safety banana jacks, 20 mm spacing
- Operating temp. range: 0°C – 60°C
- Enclosure dimensions: 70 mm x 60 mm x 140 mm
- Weight: 250 g
TBJT02
The TBJT02 is a wideband injection transformer for control loop stability measurements. It provides galvanic isolation between the swept signal source and the control loop. The injection transformer is internally terminated with a 5 Ohm resistor and protected with a 100 mA fuse. The usable frequency range is 1 Hz to 7 MHz.
- Compliance: RoHS
- Termination resistor: 5 Ω
- Fuse: 100 mA (Littlefuse 0451.100MRL); secondary (output) side
- Turns ratio: 1:1
- Characterized freq. range: 1 Hz to 100 MHz
- Usable frequency range: 1 Hz – 7 MHz
- 3 dB frequency range: 2 Hz – 3 MHz typ.
- Insertion loss (S21): 16 dB typ.
- Capacitance: 310 pF @ 1 Khz; primary to secondary winding
- DC saturation current: 12 mA
- Max. voltage rating: 600V CAT II; primary to secondary winding
- Input connector: 50 Ω BNC female,
- Output connector: 4 mm safety banana jacks, 20 mm spacing
- Operating temp. range: 0°C – 60°C
- Enclosure dimensions: 70 mm x 60 mm x 140 mm
- Weight: 300 g
More information
Visit the Tekbox page on the Electrometric website for more information