AC input 3x400 V / 3x380 V, 50/60 Hz (1) 3-phase 400 V (380/415/440/480/690 V optional), 50/60 Hz (1) 3-phase 400 V (other options on request) (1) 3-phase 400 V / 380 V, 50 Hz (1) 3-phase 400 V, 50 Hz (3)
Amplifier class Class A (4)
Amplifier Output 50 V / 16 A (1)
Amplitude Specification Range -110dBm~+13dBm (1) -110dBm~+20dBm (1)
Analog Channels 4 (37) 8 (7)
Analog modulation AM, FM, PM, Pulse (internal and optional external) (1)
Analysis Bandwidth Up to 110 MHz (1)
Antenna type Active receive dipole antenna (1) Log-periodic (1)
Antenna types High-gain horns, microwave horns (1)
Apperture 39mm (1)
Application 5G / Microwave R&D (1) 5G / Radar / Aerospace R&D (1) Cable & Antenna / RF Component Testing (1) Cable & Antenna Testing (1) EMC radiated immunity testing (1) EMC testing and microwave measurement (1) Field RF Component Testing (1) Field RF Testing (1) General RF / Wireless Testing (1) LMR / Public Safety (1) Parallel connection of 2x I-TS-3840 / 3842 / 3870 (1) Wireless / RF R&D (1)
Applications CE/EMC, automotive, military, medical, R&D (1) Automotive, military, industrial cable harness BCI immunity testing (1) BCI closed-loop level control, automotive, military current monitoring (1) CE/EMC, industrial, power supply, automotive, R&D (1) CE/EMC, power supply, industrial mains resilience, R&D (1) CE/EMC, power supply, switchgear, grid, lightning protection, R&D (1) Medical device EMC, close-proximity immunity, military RS101 (1) Military, aerospace, automotive, medical, industrial magnetic field immunity (1)
AR Models Autoranging: full power over extended V×I envelope (1)
ASA Power per channel 600 W (autoranging) (1)
ASA Total power 1,800 W (1)
ASM Power per channel 1,700 W (1)
ASM Total power 5,100 W (1)
Automation Remote control and scripting support (1)
Battery operation > 8 hours typical continuous use (1)
BCI Up to 500 mA closed-loop (1)
Bidirectional Current Up to ±2,400 A (1)
Brand AE Techron (8) Ametek Programmable Power (17) AR RF / Microwave Instrumentation (217) RIGOL (189) Tekbox (60) Teledyne LeCroy (379) Anritsu (379) Associated Research (9) Danisense (1) Eurofins E&E (22) Gustav Klein (12) Impulse Technologies (9) Lumiloop (70) Narda (73) Narda-MITEQ (22) Pacific Power Source (13) Schlöder GmbH (11)
Cabinet Dimensions 1000x310x1000 to 600x600x1900 mm (current-dependent) (1) 600x800x2000 or 1200x800x2000 mm (1) 600x800x2000 to 1200x800x2000 mm (1)
Cable series CC1, CC2, CC4 (1)
Calibration 1-Port ReadyCal, User Cal, FlexCal (1) Calibration jig and certificate supplied (1) ISO 17025 accredited (1) Supplied with calibration set and traceable calibration data (1)
Calibration methods OSL, InstaCal™, FlexCal™ (1)
Capacitance 2500-20360 uF (buffer types); 2.5-5.8 mF (local-mount MKP types) (1)
Category Spectrum Analyzer (4) Cable & Antenna Analyzer (1) Real-Time Spectrum Analyzer (1) RF Power Meter (1) Signal Analyzer (3) Signal Generator (1) USB Power Sensor (1) Vector Network Analyzer (10)
Channel configuration 2 or 4 (1) 1, 2 or 4 (1)
Communication Modbus TCP, CAN-bus, VNC over Ethernet (1) Modbus TCP, CAN-bus, VNC (standard); Profibus/Profinet/EtherCAT/LabVIEW (optional) (2) Modbus TCP/IP, VNC, CAN-bus (1)
Compatibility AR RF/Microwave systems (1)
Conducted operation Direct 50 Ω connection (1)
Configuration 1-4 inputs / 1-4 outputs, with or without switching (1)
Connectivity USB 3.0, Ethernet, Wi-Fi, GNSS (1) USB 2.0 to external PC or tablet (1)
Construction Discrete components and thin film technology (1)
Control Optional integrated control, or terminal wiring for customer automation (1)
Control interfaces Ethernet, USB, GPIB, RS-232 (1)
Controller type Modular RF test controller (1)
Cooling Air-cooled or liquid-cooled (1) Excellent thermal management; units stack without gap (1) Liquid-cooled, separate water/water heat exchanger circuit (1)
Coupling Integrated coupling network (1)
Current Up to 60 to 360 ARMS* (1) Up to 65 to 300 ARMS* (1) Up to 80 ARMS* (1) Up to 80 to 480 ARMS* (1) 16 A, 32 A, 75 A, 100 A (per phase) (1) 50 A / 100 A / 150 A per chassis (600 V) (1)
Current Accuracy 0.05 % fs (1)
Current Range up to 60 A (1) 0–1.7 A to 0–350 A (model dependent) (1) Up to 100 A (model dependent) (1) Up to 2,400 A per chassis (model dependent) (1) Up to 250 A (model dependent) (1) Up to 400 A (model dependent) (1) Up to 450 A (model dependent) (1)
Current rating 1000-4000 A (1)
DC Current up to 1200 A (1) 200-1200 A (1) 200-1200 A per channel (DC-Converter module) (1) up to 1000 A (SiC: up to 2000 A, planned) (1) up to 2000 A (1) up to 800 A (1)
DC Power 260-400 kW (1) 300-880 kW (SiC: up to 750 kW x2, planned) (1) 35-650 kW (up to 2.6 MW in parallel operation) (1) 60-550 kW (up to 660 kW overload) (1) 60-650 kW per channel (9 power levels) (1) 600-2400 kW (project-specific) (1)
DC rating up to 1000 V / 2000 A per variant shown (1)
DC voltage range 10-1500 V (3) 5-1500 V (1) 5-1500 V (6 classes: 300/600/800/1000/1200/1500 V) (1) 5-1500 V (8 classes: 80/120/300/600/800/1000/1200/1500 V) (1)
Deployment Type Portable / Embedded (1)
Design Type Tunable RF and microwave outputs (1)
Directivity High (1)
Dynamic range Up to 110 dB typical depending on frequency (1) > 80 dB (1) >105 dB (1) 147 dB (above 2 GHz) (1) 90 dB (1) Up to 127 dB typical (1)
Enclosure options Wall-mounted (600x250x800 mm), floor-standing (800x800x2000 mm), or PDSB-integrated (1)
Energy rating 500 kWs (2.0 Ohm) or 670 kWs (1.5 Ohm) (1)
Energy Recovery 96% (regenerative) (1)
Form factor Industrial high-power test chassis (rack-mountable) (1) Rack-mount industrial chassis (1) 1U half-rack (1) 1U half-rack (600 W); 2U full-rack (3/4 kW) (1) 1U rack-mount (1) 1U, 2U, 4U or 14U rack-mount (1) Benchtop (12) Handheld (8) Modular System (1) Portable (1) USB / PC-Controlled (1)
Frequency 15–1200 Hz (1) 15–5000 Hz (1) 16 Hz – 10 kHz (1) 20–500 Hz (1000 Hz optional) (1) 45–500 Hz (1) DC, 1–3000 Hz (1) DC, 15–1000 Hz (3) DC, 15–1200 Hz (2) DC, 15–200 Hz (2)
Frequency bands 1–2 GHz, 2–4 GHz, 1.2–1.4 GHz, 2.7–3.1 GHz (1)
Frequency coverage 26 MHz to 12 GHz (1) 10 MHz to 50+ GHz (1) 5 kHz to 60 GHz (1) 700 MHz to 50 GHz (1) MHz to 40+ GHz (1)
Gain 15–45 dB (2) 20–35 dB (1) 20–40 dB (2) 30–50 dB (1)
Grid perturbation THDi < 6% (1)
High-speed Arb Mode custom waveform output (1)
Housing Plastic (IP65) or metal (1)
IF Bandwidth DC to several GHz (1) DC to GHz (1)
Insertion Impedance < 2.5 Ω (1)
Insertion Loss Low (1)
Interface USB (1) Pairs with Pacific AC power sources (1)
Interfaces USB, LAN, RS232, Digital IO (1) GPIB, RS232, Ethernet (1) LXI Ethernet, USB, RS232 standard; GPIB optional (1) USB, LAN, optional GPIB (1)
Line Types Mains, signal, screened, RJ45, USB, HDMI, FireWire, CAN-BUS (1)
LO Drive Level +7 to +17 dBm (2)
Load handling 100% mismatch tolerant (high VSWR) (3) 100% mismatch tolerant (2)
Max Cable Diameter 35 mm (1) 40 mm (1) 46 mm (1)
Max Current 1000A (1) 125 A (1) 16 A per conductor (1) 2200 A (standard), up to 30 kA (modular) (1)
Max. DUT Voltage 1000 VDC (1)
Max Output Power 200 W (1)
Max parallel power Up to 1.08 MVA (12× 90 kVA) (1) 1.2 MW (1)
Max Voltage 200 Vp (1) 1000 VAC (1) 30 kV (air and contact discharge) (1) 4400 V (standard), up to 30 kV (modular) (1) 5 kV (1)
Maximum Output Frequency 500MHz (1) 5GHz (1)
Maximum parallel power Up to 1.08 MVA (1)
Maximum Power 350 W (1)
Maximum system power 975 kW (65× 15 kW in parallel) (1)
Measurement functions VSWR, Return Loss, Cable Loss, Distance-to-Fault (1)
Measurement modes Cable and antenna analyzer optional VNA optional vector voltmeter (1)
Measurement type CW and pulsed electric field (1) Average / Peak Power (model dependent) (1) Average / Peak Power (sensor dependent) (1)
Measurement Types VSWR, Return Loss, Cable Loss, Distance-to-Fault (1)
Mechanical Design Single package housing (1)
Memory Depth up to 200 Mpts (1)
Min Operating Voltage ~0.1 V at full rated current (1)
Minimum Drop/Rise Time 7µs (1)
mmWave Capability Yes (1) 54–220 GHz native, up to 1.1 THz (waveguide) (1)
Modulation Capability AM, FM, PM, Pulse + waveform generation (1)
Modulation Type AM/FM/ØM/Pulse (2)
Network 150 pF / 330 Ω (1)
Noise floor* (DANL) -163 dBm (1) −168 dBm typical (PA on) (1)
Noise Performance Optimized for low noise (1) Low noise, flat gain (1)
Operating mode Four-quadrant operation (1) Four-quadrant operation (source and sink) (1)
Operating Modes CC, CV, CR, CP (1) CC, CV, CP, CR, Dynamic CC (1) CC, CV, CP, CR, Dynamic CC, short simulation (1) CV, CC, CP (1)
Operating system Windows 10 / 11 (64-bit) (1)
Operating Temperature -55 °C to +125 °C (1) -40°C to 85°C (1)
Operation Battery powered (1) Broadband electric field generation (1)
Operation mode Four-quadrant: source + absorb (regenerative) (1)
Operation modes CW and pulsed (1)
Output 1-phase or 3-phase (2) 1-phase, 2-phase, 3-phase (6) 1-phase, 2-phase, 3-phase (selectable) (2) 1-phase, 2-phase, 3-phase dedicated (1) 1-phase, split-phase, 3-phase (1) Single-phase or three-phase (1)
Output Capacitance Low (high-speed redesign) (1)
Output connector Precision SMA (1) 50 Ω BNC (1)
Output connectors 2 × 50 Ω N-type (1)
Output Current 2.8 A to 42 A (1) Up to 60 A rms/phase (model dependent) (1) Up to 60 A rms/phase; iX2 doubles current below 50% voltage (1)
Output Frequency 25 MHz (1) 1 GHz (1) 125 MHz (1) 160 MHz (1) 40 MHz (1) 45-105 Hz standard; 15-45 / 95-420 / 195-805 Hz optional (1)
Output Impedance 3.2 mΩ in Series with 2.2 µH (1)
Output Level -130 dBm to +6/+16/+20 dBm (1)
Output level range –144 dBm to +30 dBm (with options) (1)
Output Offset <±200 µV (1)
Output Offset Current <10 mA, DC (1)
Output power 1 to 4 kVA (model dependent) (1) 2.5 to 5 kW (model dependent) (1) +5 to +15 dBm (1) ≥ +5 dBm (1) 0 to +10 dBm (1) 0 to +15 dBm (2) 10 dBm to +25 dBm (4) 10 to 20 dBm (1) 20 W to 1 kW CW (1) 20, 40, 60, 100, 200, and 300 W models (CW & pulsed) (1) Few watts to several hundred watts CW (1) Tens of watts to multi-kilowatt (1) Tens of watts to multi-kilowatt CW (1) Up to 1.7 kW (1) Up to 3000 W (1)
Output Power Range –144 dBm to +30 dBm (with options) (1)
Output Voltage 0–156 VAC (low range) / 0–312 VAC (high range) (1) 0–166 V and 0–333 V line-to-neutral (dual range) (2) 3-150 / 6-300 / 12-600 V (1-phase); 8-150 / 15-300 / 30-600 V per phase (3-phase) (1) 40 V to 600 V (1)
Output Voltage (AC) 0–200 VAC (low range) / 0–400 VAC (high range) (1)
Output Voltage (DC) 0–250 VDC (low range) / 0–500 VDC (high range) (1)
Package Type Hermetically sealed, radiation-tolerant (1)
Peak pulse power 1 kW to 150 kW (1)
Performance High gain, low VSWR (1) High directivity, low insertion loss (1) Low insertion loss, low VSWR (1) Low VSWR, broadband (1) Low VSWR, controlled beamwidth (1)
Phase Noise < –131 dBc/Hz @ 1 GHz, 20 kHz offset (typ.) (1) -102dBc/Hz@10kHz (1) -108dBc/Hz@10kHz (1) −112 dBc/Hz typical (1 GHz, 10 kHz offset) (1) Typ. –131 dBc/Hz @ 1 GHz, 20 kHz offset (1)
Phase Noise @10 kHz offset -108dBc/Hz@10kHz (1)
Phase Noise (SSB) –136 dBc/Hz (typical) @ 10 GHz, 10 kHz offset (1)
Phases 1-phase and 3-phase (selectable) (1) 1-phase and 3-phase (1) 1-phase, split-phase, 3-phase (1) Single-phase and three-phase (1)
Ports 1-Port (S11) (2) 2-Port (5) 2 or 4 ports (3) 4-Port (1)
Power 1,000 W / 1,200 W (1U) or 3,000 W (2U) (1) 1.5 kVA to 6 kVA (1) 1.7 kW / 3.4 kW / 5 kW (1U); 10 kW (2U) (1) 12 kVA to 756 kVA (1) 15 kVA to 180 kVA (1) 2,800 W (all models) (1) 30 / 45 / 55 kVA up to 1.1 MVA+ (2) 30 kVA to 1.1 MVA+ (1) 4,500 VA – 36,000 VA (1) 500 VA – 18 kVA (single chassis); up to 36 kVA paralleled (1) 500 VA to 30 kVA (parallel option) (1) 6 kVA to 180 kVA (1) 6 kVA to 756 kVA (2) 6 kW – 250 kW (water-cooled) (1) 60 kW – 1.3 MW (1) 600 W / 3,000 W / 4,000 W (1) 62.5 kVA to 625 kVA (1) 750 VA to 110 kVA (1) 850 W (1)
Power handling Very high RF power handling (1) 100 W to 10 kW CW (1) 100 W to multi-kilowatt CW (1) Frequency dependent, high power (1)
Power per chassis 5 kW – 30 kW (1–6 modules) (1)
Power (per unit) 12.5 kW / 25 kW / 37.5 kW (1) 840 W (ETS60/80/150) up to 15 kW (ETS600/1000 × 3-unit) (1) 800 W – 7,500 W (standard); custom up to 250 kW (1)
Power (single chassis) 15 kVA / 22.5 kVA / 30 kVA / 45 kVA / 90 kVA (2)
Power supply Laser power-over-fiber (1) Battery, mains (1)
Programming Front panel or remote (analog / RS232 / Ethernet on 3kW) (1)
Protection Makrolon touch-protection cover (1)
Protection Class IP20 (IP21/IP22 optional) (1) IP20 (IP54 optional) (2) IP54 (1)
Pulse width Up to 100 µs (1)
Rated power 10-200 kVA (1-phase) / 10-500 kVA (3-phase) (1)
Real-Time Analysis RTSA with 2.5 µs probability of intercept and up to 40 MHz bandwidth (1)
Real Time Bandwidth 200 MHz (1) 40 MHz (1) Up to 110 MHz (1)
Resistance 1.5 or 2.0 Ohm (1)
Resolution 16bits (2)
Resolution Bandwidth (RBW) 1Hz~10MHz (1) 1Hz~3MHz(10MHz opt.) (1)
RF Generator CDG 7000-75-10, 10 kHz – 250 MHz, 75 W (1)
RF Power 50–200 W average, up to 3 kW peak (1) 0.5 W to 6 W average (1)
Ripple & Noise < 350 µVrms / 2 mVpp (3) < 500 µVrms / 3 mVpp (1)
Safety Performance Level d (ISO 13849-1) (1) Door contact switch, stop/reset button, signal column (1)
Safety level Performance Level d (ISO 13849-1 / EN 60204-1) (1)
Sensitivity Typical DANL below −165 dBm with preamplifier enabled (1)
Sensitivity (DANL) –164 dBm with preamplifier (1)
Series/Parallel Mode one-key expandability (1)
Signal Type Analog RF (1) Broadband reference comb source (1) Noise and comb reference source (1)
Slew rate 0 to 250 VRMS; 0 to 350 VDC (1) Up to 150 V/µs (1) Up to 300 V/µs (1) Up to 60 V/µs (1) Up to 80 V/µs (1)
Software HELIA 7 (1) HELIA 7-MGA (1)
Software type Automated EMC test software (1)
SSB Phase Noise (Typ.) <-116dBc/Hz@1GHz,20kHz offset (2)
Standards IEC 61000-4-11, IEC 61000-4-27, IEC 61000-4-34 (1) IEC 60601-1-2 Ed. 4.1, IEC 61000-4-39, MIL-STD-461 RS101 (1) IEC 61000-4-11 (AC), IEC 61000-4-29 (DC) (1) IEC 61000-4-2, ISO 10605 (1) IEC 61000-4-4 (1) IEC 61000-4-5 (1) IEC 61000-4-6 (1) IEC 61000-4-6, IEC 60601-1-2 Ed. 4.1, ISO 11452-4, MIL-STD-461 CS114 (1) IEC 61000-4-6, ISO 11452-4, and MIL-STD-461 (CS114) with MT-1 (1) IEC 61000-4-6, ISO 11452-4, MIL-STD-461 CS114 (1) IEC 61000-4-6, NAMUR NE-21 (1) IEC 61000-4-8, MIL-STD-461, ISO 11452-8, DO-160 §18/19 (1)
Supported standards IEC, EN, CISPR, ISO, MIL-STD (1)
Supported tests Radiated and conducted EMC tests (1)
Sweep Speed Up to 45 GHz/s with Option 102 (1) up to 32 GHz/s (1) Up to 550 µs per data point typical (1)
Technology Traveling wave tube (TWT) (1)
Type Dual directional coupler (1) RF load attenuators and terminations (1)
Use Case Lab / Calibration / Production (1) Lab / Production / Field Testing (1)
User interface Integrated touch screen display (1)
Vector Modulation Bandwidth Up to 160 MHz RF (1)
Voltage 0 to 140 VRMS; 0 to 200 VDC (1) 0 to 250 VRMS; 0 to 350 VDC (2) 0 to 260 VRMS; 0 to 400 VDC (1) 0–300 V L-N / 520 V L-L (1) 0–333 Vac L-N / 576 Vac L-L or 425 Vdc (1) 0–350 Vac L-N / 0–606 Vac L-L; −500 to +500 Vdc (3) 0–440 Vac L-N / 762 Vac L-L; ±650 Vdc (1) 0–480 Vac L-N / 0–830 Vac L-L (2) 0–600 V (optional) (1) 0–600 Vac (2) 5–440 Vac L-N / 9–760 Vac L-L (1)
Voltage Accuracy 0.03 % fs (1)
Voltage/Current Options 30 V/5 A or 50 V/3 A (1)
Voltage Models 60 V / 120 V / 400 V / 600 V / 800 V / 1,000 V (2) ETS60 (60 Voc) / ETS80 (80 Voc) / ETS150 (150 Voc) / ETS600 (600 Voc) / ETS1000 (1,000 Voc) (1)
Voltage Range 0–20 V to 0–1,500 V (model dependent) (1) 0–40 V to 0–600 V (model dependent) (1) 0–5 V to 0–600 V (model dependent) (1) 0–6 V to 0–600 V (model dependent) (1) 0–8 V to 0–600 V (model dependent) (1) 600 VDC / 1,500 VDC / 2,000 VDC (1) 7 V – 600 V (10 models) (1) up to 150 V (1)
Voltage rating 800-1100 V DC (1)
VSWR Low (1)
Warranty 5 years (1) 3 years (1)